Master HP online three phase to three phase transformer-base UPS

The Master HP UPS, designed for large-scale applications with a power range of 100 to 600 kVA, is built on online double-conversion technology (VFI-SS-111) with an isolation transformer (IEC EN 62040-3). With an efficiency of 94.5% in online mode, an output power factor of 0.9, and output voltage distortion of less than 1% with linear loads, it is well-suited for factories, medical centers, and navigation systems. The Master HP has zero impact on input power sources (whether grid or diesel generator) when powering loads. This UPS is equipped with a delta zigzag output isolation transformer integrated directly into the inverter circuit, providing complete galvanic isolation between the inverter and connected equipment. This design enables the use of two completely separate inputs (main and bypass) from different power sources without requiring a neutral connection at the rectifier input, reducing the effects of common neutral disturbances and ensuring stable operation for sensitive loads without compromising efficiency or damaging inverter components. Additionally, the inverter transformer minimizes third harmonic effects, and the high short-circuit current capacity of the inverter (up to three times the nominal current) allows for rapid resolution of phase-to-neutral faults. The placement of the transformer within the device frame not only reduces the footprint but also enhances system configuration flexibility and installation in critical infrastructure. With a footprint of 0.85 square meters for the 250 kVA model, the Master HP is suitable for space-constrained environments. Fans located at the top eliminate the need for side or rear access, allowing the UPS to be placed against a wall. The LCD display clearly shows parameters, UPS operating status, and internal components. Features such as parallel capability for up to 8 units with N+1 redundancy, RS232/SNMP communication, and optional IP31/IP42 protection ratings (upon request) enhance the device’s versatility. The Master HP, with overload protection up to 200% for 7 seconds, provides a reliable solution for critical infrastructure.

Read more...
Topology
Online double-conversion
Power Range
100 - 600 kVA
Input/Output
3P : 3P (in:out)
Output Power Factor
P.F. = 0.9
Features:

 Galvanic isolation

 Rectifier IGBT based technology

 High efficiency up to 94.5% in online mode

 Dynamic dual bus configuration

 Up to 8 units in parallel system

 High MTBF capacity (250,000 hours)

Whats in the packing:
user manual iconUser Manual
rs232 serial cableRS232 Serial Cable
front access keyFront Door Access Key

Ask Me!

4.2 ★
  • Performance
  • Reliability
  • Features
  • Build Quality
  • Value for Price
(Generated by AI)
* Power:
* Required backup time:
Other:
- +
 Purchase Steps

 Purchase Steps

 Product Originality

 Product Originality

UPS/Model
Select Model
UPS/Input
Nominal Voltage
380, 400, 415 VAC three-phase + N
Voltage Range
400 VAC ±20% @ full load
Frequency Range
45 to 65 Hz
Power Factor
0.99 @ full load
Voltage Distortion (THDi)
< 3%
Inlet Type
terminal
UPS/Bypass
Voltage Range
380, 400, 415 VAC three-phase + N
Frequency Range
50 or 60 Hz, tolerance ±2% (selectable from ±1% to ±5%)
UPS/Output
Power
- select a model from top -
Nominal Voltage
380, 400, 415 VAC three-phase + N (selectable)
Voltage Variation
static variation ±1%, dynamic variation: EN 62040-3 class performance 1 non-linear load
Frequency Range
50 or 60 Hz (selectable), stability during battery operation 0.05%
Power Factor
0.9
Voltage Distortion (THDv)
< 1% with resistive linear load, < 3% with non-linear load
Outlet Type
terminal
Wave form
sinusoidal
Efficiency
94.5% in online mode, up to 98% in eco mode
UPS/Battery
Battery Type
external
Qty × Voltage
40 × 12 VDC = 480 VDC
UPS/Protections
Overload
110% for 60 min; 125% for 10 min; 150% for 1 min
Protections
over-current, short-circuit, over-voltage, under-voltage, over-temperature, excessive low battery
Alarms
line failure, battery low, over-load, fault conditions
UPS/Physical
Dimensions (W × D × H)
- select a model from top -
Weight
- select a model from top -
UPS/Environment
Working Temperature
ambient: min 0 °C, max 40 °C, recommended for battery life: 20 to 25 °C
Working Humidity
max 95% non-condensing
Altitude Level
1000 m @ nominal power (Derating 1% power for every 100 m above 1000 m, max 6000 m)
Noise Level
- select a model from top -
UPS/Others
Communications
2 slots for communications interface, 2 × RS232
Standards
European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage frequency Independent) VFI - SS - 111

What is the efficiency of the Master HP UPS in online mode?
The Master HP UPS achieves up to 94.5% efficiency in online double-conversion mode, minimizing energy losses and reducing operational costs. This high efficiency is particularly beneficial for data centers and industrial applications where energy savings are critical.
What battery management features are included in the Master HP UPS?
The Master HP UPS incorporates an advanced Battery Care System that includes temperature compensation, deep discharge protection, and various recharging methods. These features extend battery life and ensure optimal performance.