Updating Cart...
  • Free transportation to the installation site
  • Free initial installation and setup
  • 2-year official warranty and 10 years of after-sales service
Multi Power online three phase to three phase modular UPS

The Multi Power UPS, with a modular online topology and scalable power from 15 to 1176 kW in a three-phase to three-phase configuration, includes selectable power modules of 15, 25, and 42 kW with hot-swap capability, utilizing online double-conversion technology (VFI-SS-111) without a transformer, compliant with IEC EN 62040-3. By paralleling 28 power modules, the system's total capacity exceeds one megawatt. Its modular design allows users to easily expand capacity as load requirements increase, adding more modules at a lower cost instead of purchasing an additional UPS. With an input and output power factor of 1, input harmonic distortion below 3%, and 96.6% efficiency in online mode, this model is ideal for data centers, computer networks, and navigation systems. Various frame configurations, combining power modules, bypass, communication panel, and battery shelves, offer diverse setup options. The Auxiliary Signal Board on the rear panel facilitates connection to electrical panel switches for input, bypass, and battery control commands. The communication panel features a 7-inch touchscreen LCD display, two slots for communication equipment, two power supply units, a monitoring unit, and an RJ45 network socket. Monitoring is enabled via TCP/IP protocol by default, without requiring additional equipment. The UPS requires minimal installation space; the MPW Power Cabinet 300 PWC with seven 42 kW modules (294 kW in a 42U frame) and the MPW Combo Cabinet 130 CBC with three 42 kW modules (126 kW in a 42U frame) plus five battery units (200 units of 9 Ah batteries) with front-access design require just over half a square meter. Ultimately, the Multi Power, with its focus on scalability and minimal maintenance costs, supports sustainable infrastructure growth for dynamic applications.

Read more...
Topology
Modular Online
Power Range
45 - 294 kVA
Input/Output
3P : 3P (in:out)
Output Power Factor
P.F. = 1
Features:

Minimal space requirement

Output power factor of 1

High efficiency up to 96.5% in Online mode

High flexibility and scalability

Color LCD display with touchscreen capability

Over one megawatt with 28 modules in parallel system

Whats in the packing:
user manual iconUser Manual
usb cableUSB Cable
front access keyFront Door Access Key
hookHook for Device Transportation

Ask Me!

4.8 ★
  • Performance
  • Reliability
  • Features
  • Build Quality
  • Value for Price
(Generated by AI)
* Model:
* Power module qty.:
* Required backup time:
Other:
- +
 Purchase Steps

 Purchase Steps

 Product Originality

 Product Originality

UPS/Model
Select Model
UPS/Input
Nominal Voltage
380, 400, 415 VAC three-phase + N
Voltage Range
400 VAC ±20% @ full load
Frequency Range
40 to 72 Hz
Power Factor
0.99
Voltage Distortion (THDi)
< 3%
Inlet Type
terminal
UPS/Bypass
Voltage Range
from 180 VAC (adjustable 180 to 200 VAC) to 264 VAC (adjustable 250 to 264 VAC) referring to Neutral
Frequency Range
50 or 60 Hz, tolerance ±5% (selectable)
UPS/Output
Power
- select a model from top -
Nominal Voltage
380, 400, 415 VAC three-phase + N (selectable)
Voltage Variation
static variation ±1%, dynamic variation EN62040-3 class performance 1 non-linear load
Frequency Range
50 or 60 Hz (selectable)
Power Factor
1
Voltage Distortion (THDv)
< 1.5% with linear load, < 2.5% with non-linear load
Outlet Type
terminal
Wave form
sinusoidal
Efficiency
96.6% in online mode, up to 99% in eco mode
UPS/Battery
Battery Type
- یک مدل از بالا انتخاب کنید -
Qty × Voltage
- select a model from top -
UPS/Protections
Overload
125% for 10 min; 150% for 1 min
Protections
over-current, short-circuit, over-voltage, under-voltage, over-temperature, excessive low battery
Alarms
line failure, battery low, over-load, fault conditions
UPS/Physical
Dimensions (W × D × H)
- select a model from top -
Weight
- select a model from top -
UPS/Environment
Working Temperature
ambient: min 0 °C, max 40 °C, recommended for battery life: 20 to 25 °C
Working Humidity
max 95% non-condensing
Altitude Level
1000 m @ nominal power (Derating 1% power for every 100 m above 1000 m, max 6000 m)
Noise Level
- select a model from top -
UPS/Others
Communications
2 × RS232 + dry contacts + 2 slots for communications interface
Standards
European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 - category C2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Indipendent) VFI - SS - 111

What is the power capacity range of the Multi Power UPS?
The Multi Power UPS offers a scalable power range from 45 kVA to 1,176 kVA, accommodating various load requirements. This flexibility allows businesses to tailor their power solutions to specific needs, ensuring efficient energy management.
Can the Multi Power UPS be configured for redundancy?
Yes, the Multi Power UPS system supports parallel operation of up to four cabinets, providing N+1 redundancy. This configuration ensures continuous power supply even during maintenance or component failure, enhancing system reliability.
Home Products Downloads Call Now Your Quote