The Master MPS UPS, with a power range of 10 to 200 kVA, is a comprehensive protective system for critical loads, utilizing online double-conversion technology (VFI-SS-111) with an inverter based on an isolation transformer, compliant with the IEC EN 62040-3 standard. This model, equipped with an Efficiency Control System (ECS) to minimize system losses, an input power factor greater than 0.9, and harmonic suppression from loads, is ideal for data centers, medical equipment, and industrial factories. The MPM series is offered in three-phase to single-phase configurations from 10 to 100 kVA, while the MPT series is available in three-phase to three-phase configurations from 10 to 200 kVA. Optional 5th and 11th harmonic filters (in the HC version) and a 12-pulse rectifier for 60 and 80 kVA models (12P version) are available. The LCD display with a 240×128 pixel resolution clearly presents the UPS parameters and operating status. Scalability for up to 8 units (even with different power ratings) in distributed or centralized parallel configurations with N+1 redundancy and fault tolerance ensures high flexibility. The Master MPS can be equipped with UGS and PSJ systems upon request. The UGS system enables synchronization of two or more non-parallel UPS units, even during power outages, and can synchronize the UPS with an independent power source of different capacity. Additionally, the PSJ system allows two groups of UPS units to be connected in parallel without interruption; in case of a fault in one UPS, the faulty unit is automatically isolated, and the remaining system ensures load redundancy and power stability through an external bypass circuit. With a footprint of approximately 0.5 square meters for the 200 kVA model and an MTBF exceeding 250,000 hours, coupled with up to 98% efficiency in ECO mode, operational costs are minimized. Ultimately, the Master MPS, with galvanic isolation and high overload capacity of up to 150% for 1 minute, guarantees quality, stable power, and maximum protection for sensitive applications.

Read more...
Topology
Online double-conversion
Power Range
10 - 200 kVA
Input/Output
3P : 1-3P (in:out)
Output Power Factor
P.F. = 0.9
Features:

 Robust and reliable

 Galvanic isolation

 High overload capacity

 Small footprint

 Up to 8 units in parallel system

 High MTBF capacity (250,000 hours)

Whats in the packing:
user manual iconUser Manual
rs232 serial cableRS232 Serial Cable
front access keyFront Door Access Key

Ask Me!

4.1 ★
  • Performance
  • Reliability
  • Features
  • Build Quality
  • Value for Price
(Generated by AI)
* Model:
* Power:
* Required backup time:
Other:
- +
 Purchase Steps

 Purchase Steps

 Product Originality

 Product Originality

UPS/Model
Select Model
UPS/Input
Nominal Voltage
380, 400, 415 VAC three-phase + N
Voltage Range
400 VAC +20% -25% @ full load
Frequency Range
45 to 65 Hz
Power Factor
> 0.9 (full linear load)
Voltage Distortion (THDi)
- select a model from top -
Inlet Type
terminal
UPS/Bypass
Voltage Range
- select a model from top -
Frequency Range
50 or 60Hz (selectable) ±2% (selectable from ±1% to ±5%)
UPS/Output
Power
- select a model from top -
Nominal Voltage
- select a model from top -
Voltage Variation
- select a model from top -
Frequency Range
50 or 60 Hz (selectable), stability during battery operation 0.05%
Power Factor
0.9
Voltage Distortion (THDv)
< 1% with linear load, < 3% with non-linear load
Outlet Type
terminal
Wave form
sinusoidal
Efficiency
95% in online mode, up to 98% in eco mode
UPS/Battery
Battery Type
- select a model from top -
Qty × Voltage
- select a model from top -
UPS/Protections
Overload
110% for 60 min, 125% for 10 min, 150% for 1 min
Protections
over-current, short-circuit, over-voltage, under-voltage, over-temperature, excessive low battery
Alarms
line failure, battery low, over-load, fault conditions
UPS/Physical
Dimensions (W × D × H)
- select a model from top -
Weight
- select a model from top -
UPS/Environment
Working Temperature
ambient: min 0 °C, max 40 °C, recommended for battery life: 20 to 25 °C
Working Humidity
max 95% non-condensing
Altitude Level
1000 m @ nominal power (Derating 1% power for every 100 m above 1000 m, max 6000 m)
Noise Level
- select a model from top -
UPS/Others
Communications
2 slots for communications interface, 2 × RS232
Standards
European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage frequency Independent) VFI - SS - 111

What is the efficiency of the Master MPS UPS in online mode?
The Master MPS UPS achieves up to 94.5% efficiency in online double-conversion mode, minimizing energy losses and reducing operational costs. This high efficiency is particularly beneficial for data centers and industrial applications where energy savings are critical.
What battery management features are included in the Master MPS UPS?
The Master MPS incorporates an advanced Battery Care System that includes temperature compensation, deep discharge protection, and various recharging methods. These features extend battery life and ensure optimal performance.