Multi Sentry online three phase to three phase transformer-less UPS

The Multi Sentry UPS, with a power range of 160 and 200 kVA, is an advanced Uninterruptible Power Supply (UPS) system featuring online double-conversion technology (VFI-SS-111) compliant with the IEC EN 62040-3 standard. This device offers up to 96.5% efficiency, an input power factor of 0.99, and total harmonic distortion (THDi) of less than 2.5% (at 200 kVA), making it ideal for protecting sensitive telecommunications systems and data centers. Its high-standard technical specifications enable it to power various inductive and capacitive loads, including those with high inrush currents such as motors and compressors, without adversely affecting the output voltage. The output power factor of 1 indicates the device's high capability to supply resistive, inductive, and capacitive loads equally. The Multi Sentry features a wide input voltage acceptance range, allowing its rectifier to remain active even at voltage levels as low as 40% of the nominal voltage (at half-load capacity). This feature reduces the frequency of switching to battery mode, prevents unnecessary battery discharge, and enhances system reliability. The battery care system, including single-stage and two-stage charging, temperature compensation, and deep discharge protection, extends the lifespan of sealed lead-acid batteries. This UPS is equipped with a multilingual display, PowerShield³ software for advanced monitoring and communication (RS232, USB, SNMP). The 240×128 pixel LCD display clearly shows input, output, load percentage, and battery charge levels. The UPS operating status and internal components are displayed graphically. A manual bypass switch (Maintenance Bypass) is provided to seamlessly transfer the load from the inverter to the main input power for potential servicing. Its compact design minimizes space requirements, reducing management costs and making it a cost-effective solution for critical infrastructure.

Read more...
Topology
Online double-conversion
Power Range
160 - 200 kVA
Input / Output
3P : 3P (in:out)
Output Power Factor
P.F. = 1
Features:

Minimal space requirement

Output power factor of 1

High efficiency up to 96.5% in Online mode

Minimal impact on input sources

Parallel scalability up to 6 units

Advanced communication capabilities

Whats in the packing:
user manual iconUser Manual
rs232 serial cableRS232 Serial Cable
front access keyFront Door Access Key

Ask Me!

4.3 ★
  • Performance
  • Reliability
  • Features
  • Build Quality
  • Value for Price
(Generated by AI)
* Power:
* Required backup time:
Other:
- +
 Purchase Steps

 Purchase Steps

 Product Originality

 Product Originality

UPS/Model
Select Model
UPS/Input
Nominal Voltage
380, 400, 415 VAC three-phase + N
Voltage Range
400 VAC ±20% @ full load
Frequency Range
40 to 72 Hz
Power Factor
0.99 @ full load
Voltage Distortion (THDi)
- select a model from top -
Inlet Type
terminal
UPS/Bypass
Voltage Range
380, 400, 415 VAC three-phase + N, tolerance 180 / 264 (selectable)
Frequency Range
50 or 60 Hz, tolerance ±5% selectable
UPS/Output
Power
- select a model from top -
Nominal Voltage
380, 400, 415 VAC three-phase + N (selectable)
Voltage Variation
static variation ±1%, dynamic variation ±3%
Frequency Range
50 or 60 Hz, stability during battery operation 0.01%
Power Factor
1
Voltage Distortion (THDv)
≤ 1% with resistive linear load, ≤ 3% with non-linear load
Outlet Type
terminal
Wave form
sinusoidal
Efficiency
96.5% in online mode, up to 99% in smart active mode
UPS/Battery
Battery Type
external
Qty × Voltage
40 × 12 VDC = 480 VDC
UPS/Protections
Overload
125% for 10 min, 150% for 1 min
Protections
over-current, short-circuit, over-voltage, under-voltage, over-temperature, excessive low battery
Alarms
line failure, battery low, over-load, fault conditions
UPS/Physical
Dimensions (W × D × H)
840 × 1035 × 1900 mm
Weight
- select a model from top -
UPS/Environment
Working Temperature
ambient: min 0 °C, max 40 °C, recommended for battery life: 20 to 25 °C
Working Humidity
max 95% non-condensing
Altitude Level
1000 m @ nominal power (Derating 1% power for every 100 m above 1000 m, max 6000 m)
Noise Level
max 50 dBA @ 1 m in smart active mode (±2 dBA)
UPS/Others
Communications
3 slots for communications interface, USB, RS232
Standards
european directives: LV 2014/35/EU low voltage directive EMC 2014/30/EU electromagnetic compatibility directive standards: safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant classification in accordance with IEC EN 62040-3 (voltage frequency independent) VFI - SS - 111

What is the efficiency of the Multi Sentry UPS in online mode?
The Multi Sentry UPS achieves a maximum efficiency of 96.5% in online mode, reducing energy loss and heat generation. This high efficiency helps lower electricity and cooling costs, particularly in environments operating 24/7. This feature makes it ideal for facilities seeking sustainability and energy savings without compromising performance.
Is the Multi Sentry suitable for non-linear or IT loads?
Yes, this UPS is specifically designed to handle non-linear loads with high crest factors, common in IT and industrial systems. It maintains voltage stability and waveform integrity even with fluctuating or high-harmonic loads, making it ideal for protecting sensitive equipment and servers.
Home Products Downloads Call Now Your Quote